liquid cold plate energy storage
"
Placa de refrigeración líquida de aluminio para soluciones de gestión térmica de la batería del vehículo eléctrico
Aluminum liquid cooling plate for EV battery pack thermal management solution Alloy code Temper Tensile Strength Rm(Mpa) Yield Strength Rp0.2(Mpa) Elongation TR010,TR020,TR030,TR040, TR050,TR110,TR310,TR116, TR316,TR111,TR313,TR121, TR131,TR141,TR150, TR151,TR156 etc O 95~135* ≥35* ≥15* H14 140~185 ≥125 ≥1.5 H24 140~185 ≥125 ≥3 H16 185~225 ≥160 ≥1 H18 ≥185 - ≥0.5 TR166 etc tube material H24 185~235 ≥125 ≥8 TR116,TR316 etc tube material H14 140~185 ≥125 ≥3 TR116,TR316 etc tube
Placa de refrigeración de líquido de aleación de aluminio personalizada para dispositivos eléctricos de alta densidad de potencia
Aluminum liquid cooling plate for EV battery pack thermal management solution Alloy code Temper Tensile Strength Rm(Mpa) Yield Strength Rp0.2(Mpa) Elongation TR010,TR020,TR030,TR040, TR050,TR110,TR310,TR116, TR316,TR111,TR313,TR121, TR131,TR141,TR150, TR151,TR156 etc O 95~135* ≥35* ≥15* H14 140~185 ≥125 ≥1.5 H24 140~185 ≥125 ≥3 H16 185~225 ≥160 ≥1 H18 ≥185 - ≥0.5 TR166 etc tube material H24 185~235 ≥125 ≥8 TR116,TR316 etc tube material H14 140~185 ≥125 ≥3 TR116,TR316 etc tube
Suministro de la fábrica Placa de refrigeración de aluminio líquido para la batería cilíndrica
Factory supply aluminum liquid cooling plate for cylindrical battery pack heat dissipation Alloy code Temper Tensile Strength Rm(Mpa) Yield Strength Rp0.2(Mpa) Elongation TR010,TR020,TR030,TR040, TR050,TR110,TR310,TR116, TR316,TR111,TR313,TR121, TR131,TR141,TR150, TR151,TR156 etc O 95~135* ≥35* ≥15* H14 140~185 ≥125 ≥1.5 H24 140~185 ≥125 ≥3 H16 185~225 ≥160 ≥1 H18 ≥185 - ≥0.5 TR166 etc tube material H24 185~235 ≥125 ≥8 TR116,TR316 etc tube material H14 140~185 ≥125 ≥3 TR116
Suministro de fábrica Placa de refrigeración líquida de aluminio de batería prismática cilíndrica para vehículos eléctricos ESS
Factory supply aluminum liquid cooling plate for cylindrical battery pack heat dissipation Alloy code Temper Tensile Strength Rm(Mpa) Yield Strength Rp0.2(Mpa) Elongation TR010,TR020,TR030,TR040, TR050,TR110,TR310,TR116, TR316,TR111,TR313,TR121, TR131,TR141,TR150, TR151,TR156 etc O 95~135* ≥35* ≥15* H14 140~185 ≥125 ≥1.5 H24 140~185 ≥125 ≥3 H16 185~225 ≥160 ≥1 H18 ≥185 - ≥0.5 TR166 etc tube material H24 185~235 ≥125 ≥8 TR116,TR316 etc tube material H14 140~185 ≥125 ≥3 TR116
Placa de enfriamiento por agua de la batería EV con mecanizado CNC y diseño a prueba de fugas
Products introduction: Our high-precision brazed liquid cold plates are purpose-built for energy storage system (ESS) thermal management, delivering reliable, uniform cooling to keep battery modules within their optimal operating temperature range. Manufactured using advanced continuous brazing (CAB) technology, these cold plates feature precision-engineered flow channels that ensure even coolant distribution across the entire plate surface. This eliminates hot spots,
Caja inferior de aluminio soldada al vacío para refrigeración líquida para paquete de baterías de almacenamiento de energía 104S
Products introduction: High strength aluminum liquid cooling lower box adopting vacuum brazing and CNC precision machining Customized design exclusive for 104S battery module energy storage system Uniform powder coating surface enhances insulation corrosion resistance and outdoor adaptability Tight brazing connection ensures integral sealing performance and zero coolant leakage Reasonable internal liquid channel layout realizes efficient heat dissipation and balanced
Placa de enfriamiento líquido de soldadura fuerte de estampado de alta eficiencia de fábrica de China 3003 Al
Products introduction: Our liquid cooling plate is precision manufactured with 3003 aluminum alloy and advanced stamping brazing technology, designed to provide efficient heat dissipation for a wide range of high-power electronic devices and industrial equipment. As a core heat dissipation component, it features a sealed internal channel network that allows cooling liquid to flow smoothly, quickly absorbing and transferring heat to maintain the optimal operating temperature
3003 Placa de refrigeración líquida de aluminio con soldadura por estampado de precisión para disipación de calor de dispositivos de alta potencia
Products introduction: Our liquid cooling plate is precision manufactured with 3003 aluminum alloy and advanced stamping brazing technology, designed to provide efficient heat dissipation for a wide range of high-power electronic devices and industrial equipment. As a core heat dissipation component, it features a sealed internal channel network that allows cooling liquid to flow smoothly, quickly absorbing and transferring heat to maintain the optimal operating temperature
Estampado de alta precisión CAB soldadura de líquido bandeja de enfriamiento con PU espuma aislamiento prueba de fugas de helio batería gestión térmica placa de frío
Product Overview Trumony Aluminum's Liquid Cold Plate is engineered for the precise thermal management needs of modern Battery Energy Storage Systems. We utilize high-precision progressive die stamping to form complex flow channel geometries directly from high-quality 3003 aluminum sheet, ensuring consistent depth, flatness, and surface quality for maximum contact with battery modules. The cooling circuit is then sealed using a proprietary, flux-free joining process that